Bioevopeak 120 Tests/Hour, Dual Reagents Full-automatic Biochemistry Analyzer BA-A-120

Bioevopeak 120 Tests/Hour, Dual Reagents Full-automatic Biochemistry Analyzer BA-A-120
Características Galeria Descrição de produto Peça umas citações
Características
Especificações
Informação básica
Condições de Pagamento e Envio
Descrição de produto

Fully-auto Biochemistry Analyzer, BA-A-120

Features

  • Constant 120 test / hour with double reagent
  • 80 reagent positions
  • Automatic liquid level sensing, anti-collision protection.
  • Integrated full closed optical system, multi wavelength simultaneous detection.
  • New amorphous optical plastics reaction cups, perfect transmittance.
  • Maintenance free semiconductor solid state refrigeration
  • Friendly surface and easy to operation
  • Multifunctional precision sampling probe

    • External & internal mirror polish, external & internal probe washing
    • Dedicated sampling probe equipped with sensitive liquid sensor, timely feedback of reagent & sample residuals
    • Collision protection, automatic probe depth adjusting
  • Excellent mixer design

    • Teflon coating mixer. No water dropping(reducing carry-over)
    • Excellent mixing effect with standard mixing prosedure
  • High precision ceramic syringe

    • Permanent ceramicpiston
    • Accurate dispensing as low as 0.1µL
  • Reagent tray & Sample tray;

    • 80 reagent positions,40 sample positions
    • Non-stop cooling system with peltier pad inside, 24 hours 2℃-14℃
    • Bar code reader(optional)
  • Reaction tray

    • 50 reaction cuvettes
    • Reaction volume as low as 150μL
    • Stable & accurate temperature (37±0.1℃)for reaction
  • Advanced operating system

    • User friendly software interface simple, easy-to-operation
    • Sample automatic dilution(decrease, increase, normal)
    • Reaction result automatic checking and warning, calibaration result automatic checking, warning alarm log
    • Linear & nonlinear calibration, Multi-points calibration up to 8 points
    • Quality control apply to westgard, L-T plot, cumulative
Specifications

General information
Machine type Random access, open reagent & locked reagent (optional)
Test speed Constant 120 tests/hour (Mono reagent or double reagent)
Test principle Colorimetric method, turbidimetry
Test method 1 point end, 2 point end, Fixed-Time, Kinetics
Calibration type Linear & nonlinear
Sample unit
Sample tray 40 sample positions
Sample tube Micro cup & test tube & blood collection tube can be used. (Φ 12 -13 )mm *(25-100 )mm
Sample volume 20-300uL step by 0.1uL
Sample probe Liquid surface detection, timely tracking for liquid volume. Collision avoidance
Sample barcode Sample barcode reader (optional)
Reagent unit
Reagent tray 80 reagent positions (40 for Rl & 40 for R2), Non-stop cooling system with peltier pad inside, 24 hours 2°C-14°C, open system, could accept any reagent
Reagent volume 20-300uL, step by luL
Reagent needle Liquid surface detection, timely tracking for liquid volume. Collision avoidance
Regent barcode Regent barcode reader (optional)
Reaction unit
Reaction tray 50 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance.
Reaction volume 150uL-330uL
Reaction time 10 minutes
Temperature Peltier pad incubation system, reaction temperature (37°C ±0.1 °C)
Mixing system
Mixer paddle-type mixing, effective reducing of carry-over
Optical system
Light source Halogen lamp
Wavelength 340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm;700nm(4 more options)
Absorbance range 0-4.0 Abs
Resolution 0.0001 Abs
Operating system
Operation system Windows XP, Windows 7, Windows 8, Windows 10
Data processing Automatic calibration, test combination, effective time management of reagents, serum index, whole process detection, linear expansion of enzyme, blank deduction,dirty cuvette memory, cross infection prevention, patient information memory and association input, automatic report audit, data fuzzy query, report statistics and printing, reference range grading, alarm information classification, user operation privilege classification management.
Report printing 6 formats optional, surpport custom pattern
interface TCP/IP network interface
Working conditions
Power supply AC 110/220V ± 10%, 50/60 Hz, 650W
Water consumption 6L/hour(maximum)
Dimension 750mm*550mm *490mm(L*W*H)
Weight

70kg

Packaging & Shipping

About us

Certifications

FAQ

Q: How about quality of the goods?

A:l All the running products comply with CE standards.

l Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.

l Well-known third-party testing service available, such as SGS, BV, and TUV, etc.

Q: What are your pre- and after-sales services?

A:l Timely reply to pre-sales enquiries

l Real-time update of manufacturing and shipment status

l Contracted third-party maintenance company in over 60 countries

Assured availability of parts supply for 10 years at least

Q: Is OEM service available.

A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization.

Q: How long is the lead time:

A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.